top_hsr
var_feature
  • No overheating or burn even it overlaps each other
  • It self-regulates thermal performance in response to
    temperature
  • It can be cut to any length to suit any installation
    condition
  • Independent heat output control along the length
  • Soft switching for energy-saving and for the longer
    service time
  • Easy connection for powering and splicing.
img_hsr
var_use

Solco Pyroelec HSR Self-regulating heating cables perform the best for the below applications:

  • Freeze protection of water pipelines
    in commercial bindings
  • Temperature maintenance of industrial pipelines
  • Flexible heating appliance for medical use
var_selection code
code_hsr
var_specification
  • Max. maintain temperature(Power-on) 65℃ (149°F)
  • Max. continuous exposure(Power-off) 85℃ (185°F)
  • Rated voltage : 100 ~ 120 Vac, 200 ~ 240 Vac
  • Rated power output : 10, 16, 24 & 30 watt/m@10℃
  • Dimension(nom.)
  • HSR10,16,24 : 11.2mm x 5.6mm
  • HSR30 : 13.5mm x 5.6mm
  • Bus Wire - ASTM B355 Class 2 NPC AWG16
  • outer jacket (Optional)
  • FR polyolefin(CP)
    Exposure to aqueous inorganic chemicals
  • Fluoropolymer(CF)
    Exposure to organic chemicals or corrosives
var_approvals

FM approvals
HSRab-Cc. Self-Regulating
Electrical Heating Cable
System.
S/1/2/ABCD/T6; IP66
Cert No. 3033885

KCs approvals
HSR Self-regulation Heating
Cable System
Ex e II T6
Cert No. 11-AV2BO-0146

SGS Baseefa, ATEX
Type HSR Electrical Heating Cable system
EN 60079-0: 2012 + All : 2013
EN 60079-7: 2007
EN 60079-30-1: 2007
Ex II 2 G Ex e IIC T6 Gb
Cert No. Baseefa15ATEX0109X

LRQA, LIoyd's
Self-Regulating
Heating Cables
Cert No. 13/10027

* For More detail of certificate, click approval logo.

var_thermal output graph
graph_hsr

HSR Self-regulating heating cable complies to the below listed internation standards :

IEEE Standard 515 : 2004
- Testing, Design, Intallation, and Maintenance
of Electrical Resistance Heat Tracing
for Industrial Applications

IEC Standard 60079-30-1 : 2007
- Electrical Resistance Trace Heating

Part 30-1 : General and testing requirements
Part 30-2 : Application guide for testing,
installation, and maintenance

var_circuit breaker selection

Max. circuit length(m) based on starting temp. (℃) and breaker size (Amps)

table11
typical_hsr